Professional Supplier for Heat Exchanger & Pressure Vessel

PTFE Lined Pipe and Fitting Series

PTFE Lined Pipe and Fitting PTFE Lined Pipe and Fitting

Specification of Lined Pipes and Fittings

 
1. Range
1.1 This specification is applicable for PTFE lined pipes and fittings used for transmitting corrosive fluid. The content includes construction materials, size and test procedure of standards.
1.2 The content includes national standard 10KG level, ANSI150LBS and JIS10K specification etc.
2. Material Structure
2.1 PTFE properties
2.1.1 Temperature limitation
Continuous operating temperature 260℃
Melting point 327℃
2.1.2 Chemical resistance Resist most of chemicals. For detail information, please consult our sales engineer.
2.1.3 Frictional coefficient
Static friction coefficient 0.10
Dynamic friction coefficient 0.05
2.1.4 Proportion ASTM D792 2.14 ~ 2.2
2.1.5 Tensile strength ASTM D638 280 ~ 350Kg/cm²
2.1.6 Anti-adhesive
Surface tension 18.5dyne/cm
Contact angle
Water 104°~ 111°
Hexadecane 37°~ 45°
2.1.7 Elongation ASTM D638 100-300%
2.1.8 Water absorption ASTM D570 ﹤0.01%
2.2 PTFE liner
2.2.1 Sizes of this type of PTFE lined pipes, flanges and fittings are from 1/2″ to 12″
2.3 Iron parts
2.3.1 Pipes and fittings
Pipes and fittings are made of welded or seamless steel pipes of iron parts. And the thickness is decided by international standards and customers’ requirements.
2.3.2 Flange
Flanges are made according to any specification of international standard or ANSI150LBS or JIS10K.
3. Design Requirements
3.1 Size
3.1.1 Standard thickness of PTFE lined pipes Unit: mm
Size 1″ 1-1/2″ 2″ 3″ 4″ 6″ 8″ 10″ 12″
Standard pipe 3.0 3.0 3.0 3.0 3.5 4.5 4.5 5.0 5.0
Thickness 4.0 4.0 4.0 5.0 5.5 6.5 8.5 9.0 10.0
Note: for thickness of other PTFE lined pipes different from above and PFA lined pipes below 4″, please refer to our sales engineer.
3.1.2 Thickness of PTFE lined pipes
Size 1/2″~ 4″ Thickness of liner 3mm
6″~ 8″ 4mm
10″~ 12″ 5mm
3.1.3 Specification of size of lined flaring Unit: mm
Fitting Size 15 20 25 40 50 65 80 100 150 200 250 300
1/2″ 3/4″ 1″ 1-1/2″ 2″ 2-1/2″ 3″ 4″ 6 8″ 10″ 12″
Flaring Diameter 32 40 48 68 87 100 117 151 203 256 311 365
3.2 Vent holes
Every pipe or fitting is equipped with vent holes to release gas between liners and iron parts. Each pipe shall at least have two vent holes of 0.12″(3mm) in diameter, located at flange faces of two ends, 2″(50mm) ; each fitting shall also at least have two vent holes; and reducing flange does not have any vent hole.
4. Detection requirements
4.1 Hydraulic test Interior
pressure test will be operated at 150% of maximum work pressure. Total pressure can be reached within one minute and kept for 3 minutes.
4.2 Pinhole test
The test shall be performed with high voltage equipment (10,000 V) that shall not be destructive. After the current is connected, if any spark is produced from the probe or any pinhole warming sound is made by the detector, it means there is defect in the liner and thereby this part shall not pass quality inspection.
4.3 Visual inspection and appearance paint brush
The surface shall not have any bubble, pinhole or other defects. All defects shall be fixed before shipment. After visual inspection, an epoxy resin base coat shall be coated outside the pipes and fittings.
5. Storage, transportation and confirmation
Use wooden plate to protect lining face of flanges at each end. Therefore products will not be damaged during normal transportation. 6. Pipe fittings A value specification
6. Pipe fittings A value specification
Name Specification A value of 90
degrees elbow
A value of 45 degrees elbow A value of three-way A value of four-way A value of reducing joint
PTFE pipe DN10 70 45 70 70
PTFE pipe DN15 80 56 80 80
PTFE pipe DN20 85 60 85 85
PTFE pipe DN25 90 62 90 90
PTFE pipe DN32 100 64 100 100
PTFE pipe DN40 115 64 115 115
PTFE pipe DN50 120 68 120 120 100
PTFE pipe DN65 130 72 130 130 100
PTFE pipe DN80 140 78 140 140 100
PTFE pipe DN100 150 98 150 150 100
PTFE pipe DN125 180 108 180 180 150
PTFE pipe DN150 195 118 195 195 150
PTFE pipe DN200 220 158 200 200 200
PTFE pipe DN250 257 195 235 235 250
PTFE pipe DN300 285 226 260 260 300

Hot Tags: lined pipes and fittings, PTFE lined pipes and fittings, Teflon lined pipes and fittings